Ricoh MP C6502SP Field Service Manual page 1062

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

5. Troubleshooting
SC No.
SC336-02
SC336-03
SC336-04
SC No.
SC348-01
SC348-02
SC348-03
SC348-04
1060
Level
Error Name/Error Condition/Major Cause/Solution
D
Developer Set Error (C)
D
Developer Set Error (M)
D
Developer Set Error (Y)
When the TD sensor control voltage (Vtcnt) is 4.3V, the TD sensor output
(Vt) is less than 0.7V.
Details:
When executing TD sensor initialization (SP3-030), the machine checks
the development unit for the presence of developer. If the error condition
is detected at this point, the machine determines that there is no
developer and issues the SC.
• There is an extremely low amount of developer.
• Check the developer.
Level
Error Name/Error Condition/Major Cause/Solution
D
Toner supply error (K)
D
Toner supply error (C)
D
Toner supply error (M)
D
Toner supply error (Y)