SC No.
Level
SC547-01
D
SC No.
Level
SC547-02
D
Error Name/Error Condition/Major Cause/Solution
Zero Cross Error (Relay contact welded)
When this error occurs, machine stops with fusing relay off and displays
the SC.
• Fusing relay defective (contact welded)
• Fusing relay drive circuit defective
• Turn the main power off/on.
• If the fusing relay is damaged, replace the AC control board.
• Check the connection between the AC control board and the FSB
(fusing IOB) and replace the harness and/or circuit board if
necessary.
Error Name/Error Condition/Major Cause/Solution
Zero Cross Error (Relay contact defective)
When this error occurs, the fusing heater trigger turns off and then, after a
specified time, machine stops with fusing relay off and displays the SC.
• Fusing relay defective (contact welded)
• Fusing relay drive circuit defective
• Turn the main power off/on.
• If the fusing relay is damaged, replace the AC control board.
• Check the connection between the AC control board and the FSB
(fusing IOB) and replace the harness and/or circuit board if
necessary.
Service Call 501-595