SC No.
Level
SC185-00
D
SC No.
Level
SC186-00
D
Error Name/Error Condition/Major Cause/Solution
CIS transmission error
The data read from the ASIC register on the CIS were not as expected.
Details:
• Occurs when a serial communication error between the CIS board
and the DF board is detected. Occurs also when an error is detected
during initialization of the ASIC on the CIS.
• This can happen during initialization and feeding. The first and
second consecutive occurrences of each constitute jams. The third
occurrence constitutes an SC.
• Connector or harness between DF board and CIS board is
disconnected or defective
• ASIC on the CIS is defective
• Boot failure of ASIC on the CIS
• Reconnect the power/signal harness.
• Replace the CIS and CIPB.
• Replace the ADF main control board.
• Replace the power/signal harness.
Error Name/Error Condition/Major Cause/Solution
CIS LED error
Service Call 101-195