Ricoh MP C6502SP Field Service Manual page 1469

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

• Paper transport issues
• Flaps stick (closed) to the body of the envelope
• If the envelopes are fed in the SEF direction, they tend to warp in between the PTR unit and
fusing unit.
[A]: C6, [B]: 105x235, [C]: DLX
Cause
The heat of the fusing process may cause wrinkles to form or the adhesive on the flaps to melt if the
flaps are folded.
Solution
When feeding the types of envelopes described above, feed them from the bypass tray, in the LEF
direction (from the trailing edge), with the flaps open.
Paper Transport 003: Twining Jams
Troubleshooting for Twining Jams in the Lower Part of the Fusing Unit Caused by
Insufficient Margins
Symptom
An "accordion jam" may occur under the following conditions:
• Thin, coated paper
• A large amount of toner is needed to develop the images on the leading or trailing edge
• The margins at the leading and trailing edges are relatively narrow
Paper Transport