SC No.
Level
SC No.
Level
SC260-01
C
SC260-03
C
Error Name/Error Condition/Major Cause/Solution
When two errors were detected consecutively while monitoring the VTEC
for LD error registers in 350msec intervals after LD initialization.
Details:
The VTEC LD error flag was detected twice consecutively when the LD
turned on after initialization.
• LD degradation (LD broken, shift of output characteristics etc.)
• LD driver defective
• VTEC defective
• The interface harness damaged or not connected correctly.
• Large main scan magnification rate
• Cycle the main power off/on.
• Replace the IPU board.
• Replace the laser unit.
• Replace the LD unit.
• Replace the harness.
• Correct the main scan magnification SP*
* SP2-184-006 through 009 = 269600
SP2-102-001,007 = 123
SP2-102-016 through 025 = 0
Adjust SP2-184-006 through 009 while checking the images until
the values of SP2-102-001,007 become 123 ± 30.
Error Name/Error Condition/Major Cause/Solution
Laser Thermistor Error: Bk
Laser Thermistor Error: Ma
Service Call 202-286