Ricoh MP C6502SP Field Service Manual page 1155

Hide thumbs Also See for MP C6502SP:
Table of Contents

Advertisement

SC No.
Level
SC577-00
A
Error Name/Error Condition/Major Cause/Solution
Sensor 6: Fusing Roller Front Side: Overheat detection (software)
(T3) degrees centigrade or higher was detected for (t6) seconds
consecutively.
Number of times: 10 or more
D135 (Japan):T3 = 250, t6 = 1
D136 (Japan)/D135 (NA): T3 = 250, t6 = 1
D136 (NA)/D135 (EU)/D136(EU): T3 = 250, t6 = 1
D137 (Japan): T3 = 250, t6 = 1
D138 (Japan)/D137 (NA)/D138 (NA)/D137 (EU)/D138 (EU): T3 =
250, t6 = 1
Monitored at: All times, though SC is not issued when temperature is not
controlled (when in off mode/sleep mode, when a door, excluding the
toner supply door, is open, or when the heater relay is off).
• Triac shorted.
• IOB board defective.
• Replace the IOB board.
• Replace the unit.
Service Call 501-595
1153