5. Troubleshooting
SC No.
SC No.
SC240-01
SC240-03
1044
Level
Error Name/Error Condition/Major Cause/Solution
The FGATE signal did not turn OFF within 200 msec after the writing
process of the corresponding color ended. The FGATE signal did not turn
OFF when the next job of the corresponding color started.
Details:
• The PFGATE register of PATMOS not negated within 200 msec after
the writing process ended.
• The PFGATE register of PATMOS still asserted from the previous job
when the next writing process started.
• PATMOS defective
• Image processing ASIC defective
• Cycle the machine off/on.
• Replace the IPU board.
Level
Error Name/Error Condition/Major Cause/Solution