Primary HO2S Replacement
1. Disconnect the primary HO2S 4P connector (A).
A
2. Remove the primary HO2S (B).
44 N.m {4.5 kgf m.33lbf ft}
Installthe primary HO2S in the reverse order of
removal.
3 .
,/' .,'
,' .,
. _ . / , ,
'i>1-:l
___1-l
==
Secondary HO2S Replacement
l. Dlsconnect the secondary HO2S 4P connector (A).
2. Remove the secondary HO2S (B).
44 N.m (4.5 kgf.m,33 lbt.ft)
Inslallthe secondary HO2S in the reverse order
r e m o v a l ,
1 1 - 8 9