7. To complete the charts:
. Markthe delive ry tem peratu re along the vertical line.
. Mark the intake temperature (ambient air temperalure) along the bottom line.
. Draw a line straight up from the air temperature to the humidity.
. M a r k a p o i n t 1 0 % a b o v e a n d 1 0 % b e l o w t h e h u m i d i t y l e v e l .
. From each point, draw a horizontal line across the delivery temperature.
. The delivery temperature should fall between the two lines.
. Complete the low-side pressure test and high-side pressure test in the same way.
. Any measurements outside the line may indicate the need for further inspection.