B.1.5.6 OAP Alarm Connector
The OAP alarm connector controls the alarm condition indicators on an OAP frame.
J74 on Control Shelf backplane 04 and J69 on Control Shelf backplane 06/07
Figure B-14
(Cont.) External Alarm Connector
Pin
Signal
CUFA2
CUFA4
CUFA10
P5A48RTN
P4B48RTN
CUFA8
CUFA16
CUFA7
CUFA15
CUFA12
CUFA6
CUFA5
CUFA11

OAP Alarm Connector

Description
Signals a holdover clock critical alarm to the system when
connected to P5A48RTN (pin 10) or P4B48RTN (pin 11).
Signals a customer defined critical alarm (trouble #4) to the
system when connected to P5A48RTN (pin 10) or
P4B48RTN (pin 11).
Signals a holdover clock minor alarm to the system when
connected to P5A48RTN (pin 10) or P4B48RTN (pin 11).
Signal return path
Signal return path
Signals customer defined major alarm (trouble #8) to the
system when connected to P5A48RTN (pin 10) or
P4B48RTN (pin 11).
Signals a customer defined trouble #16 to the system when
connected to P5A48RTN (pin 10) or P4B48RTN (pin 11).
Signals a customer defined major alarm (trouble #7) to the
system when connected to P5A48RTN (pin 10) or
P4B48RTN (pin 11).
Signals a customer defined trouble #15 to the system when
connected to P5A48RTN (pin 10) or P4B48RTN (pin 11).
Signals a customer defined minor alarm (trouble #12) to the
system when connected to P5A48RTN (pin 10) or
P4B48RTN (pin 11).
Signals a holdover clock major alarm to the system when
connected to P5A48RTN (pin 10) or P4B48RTN (pin 11).
Reserved
Signals a customer defined minor alarm (trouble #11) to the
system when connected to P5A48RTN (pin 10) or
P4B48RTN (pin 11).