The following is an example of the possible output.
MEAS SS
ALARM STATUS =
service
CARD
VERSION
1107
P 101-9-000
IP LInk A
1109
101-9-000
IP Link A
CARD 1107 ALARM STATUS = No Alarms
CARD 1109 ALARM STATUS = Card is isolated from the system
Command Completed.
;
Verify the location of the primary and secondary MCPM.
2.
The primary is noted by the P beside the location in the output of rept-stat-meas.
Upgrade the secondary MCPM first.
Enter the following command to remove the secondary MCPM card from service.
3.
Do not use the force command unless this is the only MCPM card in service; MCPM
collection and reporting service should be maintained at all times.
Note:
Removing the last MCPM or only MCPM from service will cause loss of
measurements data.
If there is more than one MCPM card in service, enter:
inh-card:loc=xxxx
where xxxx is the secondary MCPM card location.
If there is only one MCPM card in service, enter:
inh-card:loc=xxx:force=yes
where xxxx is the secondary MCPM card location.
Remove the MCPM card.
4.
See
Removing a Card in an Existing EAGLE System
removed MCPM card into an ESD container; do not put it into the spare card storage
shelf. Place the new MCPM (EDSM) card into its place. Be sure the revision numbers of
the card is compatible with the EAGLE software release. If they are not, go to
the card to the software release level of the EAGLE system. If your card is compatible
with the EAGLE software release level, go to
new hardware, call the
Enter the following command to flash the card:
5.
init-flash:loc=xxxx:code=appr
PST
OOS-MT
** 0516
MEAS degraded with card out of
TYPE
PST
MCPM
IS-NR
IS-NR
MCPM
OOS-MT
OOS-MT
7
. If in doubt about the compatibility of your
My Oracle Support
(MOS).
User Upgrade Procedures
SST
AST
Fault
-----
SST
AST
Active
-----
Active
Available
Fault
-----
Fault
Unavailable
for removal procedures. Place the
Chapter 6
5
to flash
6-25