The following is an example of the possible output.
MEAS SS
ALARM STATUS =
service
CARD
VERSION
1107
P 101-9-000
IP LInk A
1109
101-9-000
IP Link A
CARD 1107 ALARM STATUS = No Alarms
CARD 1109 ALARM STATUS = Card is isolated from the system
Command Completed.
;
Verify the location of the primary and secondary MCPM.
2.
The primary is noted by the P beside the card location in the output of rept-stat-
meas.
Note:
The secondary MCPM should be upgraded before the primary MCPM.
Enter the following command to remove the secondary MCPM card from service.
3.
If there is more than one MCPM card in service, enter:
inh-card:loc=xxxx
If there is only one MCPM card in service, enter:
inh-card:loc=xxx:force=yes
where xxxx is the secondary MCPM card location.
Do not use the force command unless this is the only MCPM card in service; MCPM
collection and reporting service should be maintained at all times.
Note:
Removing the last MCPM or only MCPM from service will cause loss of
measurements data.
Remove the secondary MCPM card.
4.
See
Removing a Card in an Existing EAGLE System
Place the removed MCPM card into an ESD container.
a.
Note:
Do not put it into the spare card storage shelf.
PST
SST
OOS-MT
Fault
** 0516
MEAS degraded with card out of
TYPE
PST
SST
MCPM
IS-NR
Active
IS-NR
Active
MCPM
OOS-MT
Fault
OOS-MT
Fault
for removal procedures.
Chapter 6
User Upgrade Procedures
AST
-----
AST
-----
Available
-----
Unavailable
6-19