B.1.5.2 Remote Maintenance Center Alarm Connector
The Remote Maintenance Center Alarm connector provides system alarm condition
indicators to the remote maintenance center.
J26 on Control Shelf backplane 04 and J33 on Control Shelf backplane 06/07
Figure B-10
Table B-8
1, 3, 4, 5, 9, 11, 12 not used
2
6
7
8
Local Maintenance Center Alarm Connector
Local Maintenance Center Alarm Connector
Pin
Not used
LMCANC - Local Maintenance Center Audible Alarm, Normally Closed
LMCVMJNC - Local Maintenance Center Major Alarm, Normally Closed
LMCVMNNC - Local Maintenance Center Minor Alarm, Normally Closed
LMCVCRNC - Local Maintenance Center Critical Alarm, Normally Closed
LMCACOM - Local Maintenance Center Audible Alarm Common
LMCANO - Local Maintenance Center Audible alarm, normally Open
LMCVCOM - Local Maintenance Center Common
LMCVMJNO - Local Maintenance Center Major Alarm, Normally Open
LMCVMNNO - Local Maintenance Center Minor Alarm, Normally Open

Remote Maintenance Center Alarm Connector

Remote Maintenance Center Alarm Connector
Pin
RMCANC - Remote Maintenance Center Audible Alarm, Normally Closed
RMCMJNC - Remote Maintenance Center Major Alarm, Normally Closed
RMCMNNC - Remote Maintenance Center Minor Alarm, Normally Closed
RMCCRNC - Remote Maintenance Center Critical Alarm, Normally Closed
Control Shelf Connectors
Signal
Signal
Appendix B
B-11