User Upgrade Procedures; Upgrading To E5-Mcpm-B Module (Mcpm) - Oracle EAGLE Installation Manual

Table of Contents

Advertisement

6.3 User Upgrade Procedures

This section describes procedures for upgrading your ASM and TDM cards, and your
DSM cards loaded with the MCPM application.
This section describes procedures that include:

Upgrading to E5-MCPM-B Module (MCPM)

Measurement Collection and Polling Module (MCPM)
Removing a Card in an Existing EAGLE System
Note:
DSM and EDSM cards loaded with the MCPM application and the E5-
MCPM-B card will be referred to as "MCPM cards."
6.3.1 Upgrading to E5-MCPM-B Module (MCPM)
This procedure upgrades EDSM-2G cards with E5-MPCM-B cards. The optimal time
of day to run the procedure is between xx35 and xx58 where xx is any value between
01 and 23. The stated times provide the best opportunity for minimal interference with
normal collection and reporting operations.
Note:
Do not attempt this procedure during the first hour of the day (0000 to 0059).
Note:
Throughout this document, the term MCPM refers to both the E5-MCPM-B
(P/N 870-3089-xx) and the EDSM-2G loaded with the MCPM application
(P/N 870-2372-03) cards unless specifically noted otherwise.
The Primary MCPM card performs all measurements collection and reporting functions
and provides on-card RAM storage for collected data and scheduled reports. The
Secondary MCPM provides a redundant backup for the Primary module, and assumes
collection and reporting responsibilities on the loss of the Primary. TCP/IP connections
are used to deliver measurement reports from the Primary MCPM card to the
customer via an FTP client. The FTP configuration can be customized to support
automatic transfer of scheduled reports from the client to the server.
Enter the following command to determine the status and number of the MCPM
1.
cards.
rept-stat-meas
Chapter 6
User Upgrade Procedures
6-18

Advertisement

Table of Contents
loading