Hs Source And Composite Clock Cables On Backplane P/N 850-0330-03/04 - Oracle EAGLE Installation Manual

Table of Contents

Advertisement

Command Completed.
Refer to
Verify that you don't have any new alarms, refer to the recorded output obtained in
21.
4. If you check the system for clock alarms, the output should show no clock
errors; enter:
rept-stat-trbl
You have completed the cable replacement procedure for the high‑speed source and
composite clock cables on EAGLE systems with backplane (P/N 850‑0330‑06/07).
6.5.2 HS Source and Composite Clock Cables on Backplane P/
N 850‑0330‑03/04
On systems with control shelf backplane (P/N 850‑0330‑03/04), the high‑speed source
clock cable (P/N 830‑0873‑xx or P/N 830‑1189‑xx) sends only high‑speed clock
signals to the EAGLE. The existing composite clock cables (P/N 830‑0226‑xx)
continue to provide the low‑speed clock connections to connectors J42 and J41
(Primary BITS and Secondary BITS) on the backplane. The HS cables (P/
N 830‑0873‑xx or P/N 830‑1189‑xx) send the HS primary and secondary clock signals
through adapter cables (P/N 830‑0846‑01) to connectors J57 and J56 on the
backplane. The two connectors are labeled ACLK3 and ACLK4.
This procedure describes the steps required to install the HS clock cables on the
EAGLE with control shelf backplane (P/N 850‑0330‑03/04) using adapter cable (P/
N 830‑0846‑01).
Caution:
A system with DS0A links cannot run without a composite clock source. This
procedure requires removing and replacing the ACLK3 cables to frame 3
(shelves 4100, 4200, 4300) and frame 4, ACLK4 (shelves 5100, 5200, 5300).
Take extreme caution when removing and replacing the ACLK cables.
Remove one cable at a time and confirm before removal that the BCLK clock
source is active to that frame.
PSTSSTAST
5
for output legend
Note:
There should be no bad clocks present in the output of the rept-stat-clk
command. If bad clocks are present, contact the
(MOS)
for assistance.
Note:
There should be no clock error messages present in the output of the
rept-stat-trbl command. If clock error messages are present, contact the
My Oracle Support (MOS)
My Oracle Support
for assistance.
Chapter 6