Fuses; Fuse And Alarm Panel (P/N 870-2804-01) - Oracle EAGLE Installation Manual

Table of Contents

Advertisement

5.1.1 Fuses

The fuse and alarm panel uses GMT-type fuses of different amperage ratings for
individual circuit protection. If a frame circuit fuse is blown the alarm is indicated by an
LED on the front panel and a small colored flag on the fuse shows the fuse that has
failed (refer to
the FAP assembly.
Caution:
Always use a fuse of the same type and amperage rating when replacing a
failed fuse.
Figure 5-1
Table 5-1
Fuse Amp
0.18A
0.2A
0.25A
0.33A
0.375A
0.5A
0.65A
0.75A
1A
1.33A
1.5A

5.1.2 Fuse and Alarm Panel (P/N 870-2804-01)

The FAP (P/N 870-2804-01) is a low-profile (1U) unit that can be installed in the
Control Frame (CF) and the Extension Frame (EF).
Figure
5-1. Refer to Maintenance for procedures on replacing fuses and
Fuse (GMT Brand Shown)
Fuse Color Codes of Alarm Flags
Fuse Flag Color
Orange-Red
Black-Red
Violet
Yellow-Green
White-Green
Red
Black
Brown
Gray
White
White-Yellow
Fuse and Alarm Panels
Fuse Amp
Fuse Flag Color
2A
Orange
2.5A
White-Orange
3A
Blue
3.5A
White-Blue
4A
White -Brown
5A
Green
7.5A
Black-White
10A
Red-White
12A
Yellow-Green
15A
Red-Blue