Oracle EAGLE Installation Manual page 26

Table of Contents

Advertisement

warning:
Metal points on Printed Circuit Boards conducts -48VDC and can cause shorts,
shocks, and damage if not handled properly.
Caution:
New CPCI cards may have a small plastic cover over the screws or the alignment
ejector pins. Remove and discard these plastic covers. If inserting the cards takes
an excessive amount of force, check for obstructions. Forcing the card into a slot
may damage the ejector handle or pin.
Caution:
In EAGLE, make sure that the DCM card is inserted into the correct odd numbered
7
slots. In IP
Secure Gateway systems, there are no slot provisioning requirements.
Cards may be provisioned in any slot where they physically fit except for the HMUX
and MAS dedicated card slots.
Caution:
After the frame has been shipped or moved, remove all cards prior to applying
power. Carefully reset cards to avoid possible faulty connections.
To remove or install a card, use the module locking tabs at the top and bottom of the card
faceplate. See to
Figure
2-1.
Figure 2-1
Removing a Card
Caution:
Do not impact the faceplate in order to mate the connectors. Any impact to the
card's faceplate can damage the faceplate, the pins, or the connectors.
Chapter 2
Components
2-7