The system returns output similar to the following:
tekelecstp 00-12-10 11:35:15 EST Rel 26.0.0
CARD LOC = 1114 (Active
PRIMARY BITS
= Fault
SECONDARY BITS
= Active
PSTSSTAST
SYSTEM CLOCKIS-NRActive-----
# Cards using CLK A = 11
# Cards using CLK B = 3
# Cards using CLK I = 0
PSTSSTAST
Command Completed.
Refer to
2
for output legend.
Caution:
If cards on shelves 4100, 4200, and 4300 indicate bad ACLK and BCLK
reconnect the ACLK3 cable to connector J57 and abort this procedure. Contact
the
My Oracle Support (MOS)
Note:
In the following steps reference
Connect the adapter cable (P/N 830‑0846‑01) P1 (DB25) to ACLK3 connector J57 on the
11.
control shelf backplane. Tighten the connector with a slotted screw driver.
) CARD LOC = 1116 (Standby
PRIMARY BITS
= Fault
SECONDARY BITS
= Active
# Cards with bad CLK A = 0
# Cards with bad CLK B = 0
for assistance.
Figure 6-36
for cabling connections.
Chapter 6
Source Timing
)