Figure 6-36
High-Speed source Timing Adapter Cable (P/N 830‑0846‑01)
Connect the adapter cable (P/N 830‑0846‑01) P2 (DB25) to the end of the ACLK
12.
cable removed in Step\ Tighten the connector with a slotted screw driver.
This step reconnects the ACLK3 signals to shelves 4100, 4200, 4300.
At the terminal, the EAGLE displays messages indicating return of ACLK to cards
on shelves 4100, 4200, and 4300 with BCLK normal.
Connect the primary HS source clock cable (P/N 830‑0873‑xx) connector end to
13.
adapter cable (P/N 830‑0846‑01) P3 (DB15). Tighten the connector with a slotted
screw driver.
This step connects the customer primary HS clock source to the TDM card
through the unused contacts of the ACLK3 connector J57.