Control shelves with backplane P/N 850‑0330‑06 or ‑07 or later using HS Source and
composite clock cables P/N 830‑0873‑xx or P/N 830‑1189‑xx.
Note:
Replace the existing composite clock cables (P/N 830‑0226‑xx) with RS422
compatible HS Source and composite clock cables P/N 830‑0873‑xx or P/
N 830‑1189‑xx. For control shelves with backplane (P/N 850‑0330‑06 or ‑07 or
later), connect the cables to J48 and J49 (primary and secondary BITS) and
connect the other ends to the site clock sources.
Note:
Control shelf backplane (P/N 850‑0330‑05) cannot be used with the HMUX card
required to implement the Large System feature.
ATMLIM card(s) or E1/T1MIM(s)
High‑speed clock source (T1 or E1)
T1 clock source (RS422 compatible), 1.544 MHz ± 200 Hz square wave output.
E1 clock source (RS422 compatible), 2.048 MHz ± 103 Hz square wave output.
ITU G.703 Sec 5 UnFramed T1
T1-T1.101 /T1-T1.102 Framed T1
E1-G.703-sec. 9 Framed E1
E1-G.703-sec. 13 Unframed E1
Source Timing Feature Requirement Matrix
Use
Table 6-2
to identify the hardware or software that is required to prepare your EAGLE
STP for the HS Source Timing feature. Perform the procedures in the order listed. Skip any
procedure that does not apply.
Note:
Perform the procedures mentioned in this document during a maintenance window.
Table 6-2
Feature Requirement Matrix
If you do not have...
Control shelf backplane
Replace the backplane
P/N 850‑0330‑06 or ‑07
or later
do this...
using procedures...
My Oracle
Contact
Support (MOS)
assistance.
Chapter 6
Source Timing
Notes
for
6-55