Table 6-6
Physical Conditions
Insertion force
Withdrawal force
Life
Humidity
Moisture Resistance
Salt Spray
Temperature
Thermal Shock
Figure 6-54
120 Ohms Converter Rear
Ohms Converter International Market
Mechanical
4.17lb (1.9kg) average
5.21lb (2.4kg) average
Minimum 20,000 insertion/withdrawal cycles
Environmental
To 95% (operating and non-operating)
Per MIL-STD-202F, Method 106E
Per MIL-STD-202F, Method 101D
–40 to 149˚F (–40 to 65˚C) operating
–67 to 185˚F (–55 to 85˚C) non-operating
Per MIL-STD-202F, Method 107D
Chapter 6
6-106