danger:
Always wear a wrist strap or other electrostatic protection when handling printed
circuit cards and other electrostatic-sensitive devices.
Recommended Tools
Oracle tools should be labeled "Property of ORACLE" with either a press-on Field Tool
Identification label or Field Tool Identification wrap.
Safety glasses
Tie-wrap tool
Diagonal cutters
Flush cutters
Wire-wrap gun and bit
Slotted screwdriver with 1/8-inch blade and 8-inch shank
Stripper
Heat gun

6.7.1 Alarm Cable Termination

The rack alarm cable for the control frame may be factory installed at both ends or the row
alarm cable may come from the factory installed at the alarm end-panel only.
danger:
Always wear a wrist strap or other electrostatic protection when handling printed
circuit cards and other electrostatic-sensitive devices.
warning:
Always trim tie-wraps flush and turn the trimmed tie-wraps to the rear of the cable
bundle, when facing the back of the frame.
The rack alarm cables lead from ports in the system control backplane and connect with
other frames in the row.
The backplane alarm ports are:
FAP (Frame and Alarm Panel) in the control frame J13 on 850-0330-06 or -07
FAP extension frame 00 J15 on P/N 850-0330-06 or -07
FAP extension frame 01 J32 on P/N 850-0330-06 or -07
FAP extension frame 02 J46 on P/N 850-0330-06 or -07
FAP extension frame 03 J61 on P/N 850-0330-06 or -07
Termination of Alarm, Clock Supply, and Terminal Cables
Chapter 6
6-93