Setting Up The Pri Network Interface - Polycom ViewStation FX4000 User Manual

Hide thumbs Also See for ViewStation FX4000:
Table of Contents

Advertisement

ViewStation FX/VS4000 User Guide

Setting up the PRI Network Interface

52
extend the distance between your ViewStation FX or VS4000 and the
V.35/RS-449 network interface module.
V.35/RS-449 and RS-366 Connections. The V.35/RS-449 connection
on the V.35 cable is used for data and the RS-366 connection is used
for dialing. If you plan to place 2 x 56 Kbps or 2 x 64 Kbps calls, use
one cable for each port.
If your DCE does not use dialing, do not use the RS-366 (DB-25M)
connector.
LED Information. Refer to the V.35/RS-449 Technical Information
section of the Polycom Office Integrators' Reference Manual.
This section explains how to install and connect the PRI network
interface module so that you can make calls over ISDN with the
ViewStation FX or VS4000 system. The information applies to both
the PRI E1 and the PRI T1 network interfaces.
To connect the PRI network interface module to the
ViewStation FX or VS4000:
1.
Power off your ViewStation FX or VS4000.
2.
Plug the 12-volt DC power supply into the PRI network
interface module and then into the wall jack.
Note
www.polycom.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Viewstation vs4000

Table of Contents