Install a new erase lamp, (35 ppm)
PL 9.22 Item
The fault may be intermittent. Perform the steps that follow:
Check the wiring,
GP 7
between
P/J41
Ensure that the P/Js are correctly and securely connected.
Malfunction of the following associated circuits can cause 09-350 faults.
The inverter paper path and Inverter nip solenoid, go to
Exit Sensor RAP.
The vacuum transport fan and Registration clutch, go to
Lead Edge Late to Fuser Exit Sensor RAP.
P/J41
Erase lamp
Figure 1 Component location
Xerox® WorkCentre® 5790 Family
1, (40-90 ppm)
PL 9.20 Item
1.
and
P/J17
on the LVPS.
10-120, 10-121, 10-126
10-101A, 10-102A, 10-103A
Erase lamp
IOT
May 2013
2-263
Figure 2 Circuit diagram
Status Indicator RAPs