A
B
Install a new erase lamp, (35 ppm)
PL 9.22 Item
The fault may be intermittent. Perform the steps that follow:
•
Check the wiring,
GP 7
between
P/J41
•
Ensure that the P/Js are correctly and securely connected.
•
Malfunction of the following associated circuits can cause 09-350 faults.
–
The inverter paper path and Inverter nip solenoid, go to
Exit Sensor RAP.
–
The vacuum transport fan and Registration clutch, go to
Lead Edge Late to Fuser Exit Sensor RAP.
P/J41
Erase lamp
Figure 1 Component location
Xerox® WorkCentre® 5790 Family
1, (40-90 ppm)
PL 9.20 Item
1.
and
P/J17
on the LVPS.
10-120, 10-121, 10-126
10-101A, 10-102A, 10-103A
Erase lamp
IOT
May 2013
2-263
Figure 2 Circuit diagram
Status Indicator RAPs
09-350