Commissioning preparations for PROFIBUS

2.4 DRIVE-CLiQ interface for CU305

3. The Control Unit's PPI address is pre-set to "3" in the factory.
4. Also set the bus address to "3" during set-up, or under "properties" in the drive unit
5. A null modem cable must be used to connect the PC (COM interface) to the Control Unit.
2.4
DRIVE-CLiQ interface for CU305
The CU305 has a DRIVE-CLiQ interface. You may connect exactly one of the following
components to this interface:
● SMI motor
● 1 encoder of type SMC10, SMC20, SMC30, SME20 or SME25
Further components or connections to the DRIVE-CLiQ interface are not permitted and lead
to errors in the drive system.
42
context menu.
Figure 2-3
Setting the bus address
This interface must not be switched.
Function Manual, 10/2008, 6SL3097-4AB10-0BP0