Bit
Meaning
8
Speed
setpoint-actual value deviation
within tolerance band
9
Control request to PLC
10
f or n comparison value reached or
exceeded
Note:
The message is parameterized as follows:
p2141 Threshold value
p2142 Hysteresis
11
I, M or P limit reached or exceeded
12
Holding brake open
13
No motor overtemperature alarm
14
n_act >= 0
15
Alarm, drive converter thermal
overload
Drive functions
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
1
Setpoint-actual value monitoring within tolerance
band
Actual value within a tolerance band; dynamic
overshoot or undershoot for t < t
e.g.
n = n
±
set
f = f
±, etc.,
set
t
can be parameterized
max
0
Setpoint/actual value monitoring not within
tolerance band
1
Control requested
The PLC is requested to assume control. Condition
for applications with isochronous mode: drive
synchronized with PLC system.
0
Local operation
Control only possible on device
1
f or n comparison value reached or exceeded.
0
f or n comparison value not reached.
1
I, M or P limit not reached
0
I, M or P limit reached or exceeded
1
Holding brake opened
0
Holding brake closed
1
Motor overtemperature alarm not active
0
Motor overtemperature alarm active
1
Actual speed > = 0
0
Actual speed < 0
1
No alarm present
0
Alarm, converter thermal overload
The overtemperature alarm for the converter is
active.
Communication PROFIBUS DP
9.1 Communication according to PROFIdrive
Remarks
permissible,
max
BICO
BO: r2197.7
BO: r0899.9
BO: r2199.1
BO: r1407.7
BO: r0899.12
BO: r2135.14
BO: r2197.3
BO: r2135.15
407