Acceptance Test And Acceptance Report; General Information - Siemens Sinamics S110 Function Manual

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

8.9

Acceptance test and acceptance report

8.9.1

General information

Requirements regarding acceptance tests are derived from the EC Machinery Directive and
ISO 13849-1. IEC 22G WG 10 is currently working on a "Functional safety" standard which
includes a detailed description of acceptance test requirements. The machine manufacturer
(OEM) is committed accordingly
● to carry out an acceptance test for safety-related functions and machine parts
● to issue an "Acceptance certificate" which describes the test results.
The acceptance test for systems with Safety Integrated Extended Functions (SI functions) is
focused on validating the functionality of Safety Integrated monitoring and stop functions
implemented in the drive system. The test objective is to verify proper implementation of the
defined safety functions and of test mechanisms (forced dormant error detection measures)
and to examine the response of specific monitoring functions to the explicit input of values
outside tolerance limits. This has to be conducted for all drive-specific Safety Integrated
motion monitoring procedures.
A new acceptance test must be carried out if any changes were made to SI function
parameters and must be logged in the acceptance report.
Note
The acceptance test is designed to ensure that the safety functions are correctly
parameterized. The measured values (e.g. distance, time) and the system behavior identified
(e.g. initiation of a specific stop) can be used for checking the plausibility of the configured
safety functions. The objective of an acceptance test is to identify potential configuration
errors or to record the valid configuration. The measured values are typical but no worst
case values. They represent the behavior of the machine at the time of measurement. These
measurements cannot be used, for example, to derive maximum ramp-down values.
Drive functions
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
WARNING
Safety Integrated Functions
8.9 Acceptance test and acceptance report
359