Communication PROFIBUS DP
9.1 Communication according to PROFIdrive
9.1.3.3

Description of status words and actual values

Description of status words and actual values
Note
This chapter describes the assignment and meaning of the process data in SINAMICS
interface mode (p2038 = 0).
The reference parameter is also specified for the relevant process data. The process data
are generally normalized in accordance with parameters p2000 to r2004.
The following scalings also apply:
A temperature of 100°C = 100%
An electrical angle of 90° also = 100%.
Overview of status words and actual values
Table 9- 13
Overview of status words and actual values, profile-specific
Abbreviation
ZSW1
Status word 1
ZSW2
Status word 2
NACT_A
Speed setpoint A (16 bit)
NACT_B
Speed setpoint B (32 bit)
G1_ZSW
Encoder 1 status word
G1_XIST1
Encoder 1 actual position value 1
G1_XIST2
Encoder 1 actual position value 2
G2_ZSW
Encoder 2 status word
G2_XIST1
Encoder 2 actual position value 1
G2_XIST2
Encoder 2 actual position value 2
E_DIGITAL
Digital inputs (16 bits)
XIST_A
Pos position actual value
AKTSATZ
Pos selected block
1) Data type according to PROFIdrive profile V4:
I16 = Integer16, I32 = Integer32, U16 = Unsigned16, U32 = Unsigned32
2) Bit-serial interconnection: Refer to the following pages, r2089 via binector-connector converter
404
Name
Signal
Data type
1)
number
2
U16
4
U16
6
I16
8
I32
10
U16
11
U32
12
U32
14
U16
15
U32
16
U32
21
U16
28
I32
33
U16
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
Interconnection
parameters
r2089[0]
r2089[1]
r0063
r0063
r0481[0]
r0482[0]
r0483[0]
r0481[1]
r0482[1]
r0483[1]
r2089[2]
r2521[0]
r2670
Drive functions