Copying parameter data sets from non-volatile memory to the memory card
There are three ways of copying parameter data sets from non-volatile memory to the
memory card:
1. The system is powered down:
2. The system is switched on:
3. The system is switched on:
● The user starts data transmission from the ROM to the memory card with parameters
Note
RAM to ROM transfer will overwrite the content of an inserted memory card.
When a memory card is inserted, the RAM to ROM command (p0977[1]) will copy the
parameter data set with the index 0 from the ROM to the memory card. Any previously saved
parameter data set will be overwritten.
Drive functions
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
– Insert an empty memory card into the CU305.
– Switch on the system.
– The system is put into operation by the firmware in the "ROM".
– Then the complete up-to-date parameter data set with the index 0 is copied from the
"ROM" to the memory card automatically and without a prompt appearing.
– Insert a memory card into the CU305.
– Execute command "RAM to ROM" (p0977[1]). The up-to-date parameter data set is
copied automatically, first to the "ROM" and then to the memory card (in the latter
case as a data set with the index 0). If the memory card already contains a parameter
data set with the index 0, this will be overwritten without a prompt appearing.
p0802, p0803 and p0804:
– p0804 = 1, p0802 = (0...100) as target (to the memory card) and p0803 = (0/10/11/12)
as source (from the "ROM").
Basic information about the drive system
10.3 Working with the memory card