Siemens Sinamics S110 Function Manual page 409

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

Bit
Meaning
8
Following error within the tolerance
range
9
Control request to PLC
10
Target position reached
11
Reference point set
12
Acknowledgement, traversing
block activated
13
Drive at standstill
14*
Axis accelerating
(telegram 111)
15*
Axis decelerating
(telegram 111)
Drive functions
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
1
Setpoint-actual value monitoring within tolerance
band
Actual value within a tolerance bandwidth;
The tolerance bandwidth can be parameterized.
0
Setpoint/actual value monitoring not within
tolerance band
1
Control requested
The PLC is requested to assume control. Condition
for applications with isochronous mode: drive
synchronized with PLC system.
0
Local operation
Control only possible on device
1
Target position reached
0
Target position not reached
1
Reference point set
0
Reference point not set
0/1
Acknowledgement, traversing block
0
No effect
1
Drive at standstill
0
Drive not at standstill
1
Axis is accelerating.
0
Axis is not accelerating.
1
Axis is decelerating.
0
Axis is not decelerating.
Communication PROFIBUS DP
9.1 Communication according to PROFIdrive
Remarks
BICO
BO: r2684.8
BO: r0899.9
BO: r2684.10
BO: r2684.11
BO: r2684.12
BO: r2199.0
BO: r2684.4
BO: r2684.5
409