Siemens Sinamics S110 Function Manual page 212

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

Drive functions
7.3 Function modules
Configuration of the load gear (p2720).
The following points can be set by configuring this parameter:
● p2720.0: Activation of position tracking
● p2720.1: Setting the axis type (linear or rotary axis)
● p2720.2: Reset position
Note
If position tracking of the load gear is activated with parameter p2720[0]=1 (position gear
load tracking) after the encoder is adjusted (p2507=3), the adjustment will be reset.
If the encoder is adjusted again when load position tracking is active, the load gear position
will be reset (overflows).
The permissible position tracking range is mapped onto the reproducible encoder range of
EPOS.
Virtual multiturn encoder (p2721)
The virtual multiturn resolution is used to set the number of resolvable motor rotations for a
rotary absolute encoder with activated position tracking. It can be edited only for rotary axes.
With a rotary absolute encoder (p0404.1 = 1) with activated position tracking (p2720.0 = 1),
p2721 can be used to enter a virtual multiturn resolution.
Note
If the gear factor is not equal to 1, then p2721 always refers to the load side. The virtual
resolution, which is required for the load, is then set here.
For rotary axes, the virtual multiturn resolution (p2721) is preset to the value of the multiturn
resolution of the encoder (p0421) but may be changed.
Example: Singleturn encoder
Parameter p0421 is preset to p0421 = 1. However, parameter p2721 can be altered
subsequently, e.g. the user can program p2721 = 5. As a result, the encoder evaluation
initiates 5 load rotations before the same absolute value is achieved again.
For linear axes, the virtual multiturn resolution (p2721) is preset to the multiturn resolution of
the encoder (p0421) extended by 6 bits (max. overflows 32 positive/negative)
The value for p2721 cannot be edited again afterwards.
212
Here, a rotary axis refers to a modulo axis (modulo offset can be activated through
higher-level control or EPOS). With a linear axis, position tracking is mainly used to
extend the position area (see section: Virtual multiturn encoder (p2721)).
The position values stored in non-volatile memory are reset in response to the following
events:
– When encoder replacement is detected.
– When the configuration of the encoder data set (EDS) is modified.
– When the absolute encoder is adjusted again.
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
Drive functions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents