Siemens Sinamics S110 Function Manual page 474

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

Basic information about the drive system
10.3 Working with the memory card
Copying parameter data sets from the memory card to non-volatile memory
There are two ways of copying parameter data sets from the memory card to non-volatile
memory:
1. The system is switched off:
2. The system is switched on. The user starts data transmission from the memory card to
Important parameters:
p0977: Save all parameters (for more information, see the S110 List Manual).
p0802: Data transfer of parameters [0,10,11,12], memory card as source or target.
p0803: Data transfer of parameters [0...100], non-volatile device memory as source or target.
p0804: Start of parameter data transfer and specification of transfer direction:
● p0804 = 1 : Transfer from the memory card to non-volatile device memory,
● p0804 = 2: Transfer from non-volatile device memory to memory card.
474
– Insert a memory card containing a parameter data set with the index 0 into the CU305.
– Switch on the system. The new parameter data set will be copied to the ROM
automatically. The parameter data set with the index 0 which was previously available
in the ROM will be overwritten.
– The system will then boot with the new parameter data set.
the ROM with parameters p0802, p0803 and p0804:
– p0804 = 2.
– p0802 = (0...100) as source (from the memory card) and p0803 = (0/10/11/12) as
target (to the "ROM").
Note
The parameter data set in the "ROM" is overwritten during system start-up.
If a memory card with a parameter data set is inserted when the system is switched
on, the parameter data set with the index 0 in the "ROM" will be overwritten by the
new one with the index 0 on the memory card.
Function Manual, 10/2008, 6SL3097-4AB10-0BP0