Basic information about the drive system
10.1 Parameter
The CDS and DDS can be switched over during normal operation. Further types of data set
also exist, however these can only be activated indirectly by means of a DDS changeover.
● EDS Encoder Data Set
● MDS Motor Data Set
Saving parameters in a non-volatile memory
The modified parameter values are stored in the volatile RAM. When the drive system is
switched off, this data is lost.
So that the changes can be restored, the data must be saved as follows in a non-volatile
manner in the Control Unit.
● Save parameters - device and drive
● Save the parameters with STARTER
464
Figure 10-2
Parameter categories
p0977 = 1; automatically reset to 0
See "Copy RAM to ROM" function
NOTICE
The power supply to the Control Unit may first be switched off after saving has finished
(i.e. after saving has started, wait until it has finished and parameter p0977 has the
value 0 once more).