With ramp-function generator tracking
● At p1145 > 1 (values between 0 and 1 are not applicable), ramp-function generator
● t1 and t2 almost identical
Function diagrams (see SINAMICS S110 List Manual)
● 1550 Setpoint channel
● 3060 Basic ramp-function generator
● 3070 Extended ramp-function generator
● 3080 Ramp-function generator selection, status word, tracking
Signal overview (see SINAMICS S110 List Manual)
● Control signal STW1.2 OFF3
● Control signal STW1.4 Enable ramp-function generator
● Control signal STW1.5 Start/stop ramp-function generator
● Control signal STW1.6 Enable setpoint
● Control signal STW2.1 Bypass ramp-function generator
Parameterization with STARTER
The "ramp-function generator" parameter screen is selected via the following icon in the
toolbar of the STARTER commissioning tool:
Figure 7-65
Drive functions
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
tracking is activated when the torque limit is approached. The ramp-function generator
output thereby only exceeds the actual speed value by a deviation value that can be
defined in p1145.
STARTER icon for "ramp-function generator"