Analog Input - Siemens Sinamics S110 Function Manual

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

10.5.3

Analog Input

Figure 10-10 Analog inputs: Signal processing for the AI0
Properties
● Hardware input filter set permanently
● Simulation mode parameterizable
● Adjustable offset
● Signal can be inverted via binector input
● Adjustable absolute-value generation
● Noise suppression (p0768)
● Enabling of inputs via binector input
● Output signal available via connector output
● Scaling
● Smoothing
Function diagram (see SINAMICS S110 List Manual)
● 2040 Analog input (AI 0)
Drive functions
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
NOTICE
Scaling parameters p0757 to p0760 do not limit the voltage/current values.
Basic information about the drive system
10.5 Inputs/outputs
485