Diagnostics
5.2 Diagnostics via STARTER
● Restriction of the output signal to the minimum and maximum value settable.
● Operating modes of the function generator
Injection points of the ramp-function generator
Figure 5-2
Further signal shapes
Further signal shapes can be parameterized.
Example:
The "triangular" signal form can be parameterized with "upper limitation" to produce a
triangle with no peak.
Figure 5-3
Starting/stopping the ramp-function generator
Note
With the corresponding ramp-function generator parameter settings (e.g. offset), the motor
can "drift" and travel to its end stop.
The movement of the drive is not monitored while the ramp-function generator is active.
92
– Connector output
– Current setpoint downstream of filter (current setpoint filter)
– Disturbing torque (downstream of current setpoint filter)
– Speed setpoint downstream of filter (speed setpoint filter)
– Current setpoint upstream of filter (current setpoint filter)
– Speed setpoint upstream of filter (speed setpoint filter)
Injection points of the ramp-function generator
"Triangular" signal without peak
Function Manual, 10/2008, 6SL3097-4AB10-0BP0