Table 7- 14
Data determined using p1960 for synchronous motors (rotating measurement)
Determined data
r1934 q inductance identified
r1935 q inductance identification current
Note:
The q inductance characteristic can be used as basis to manually determine the data for the current controller adaptation
(p0391, p0392 and p0393).
r1937 torque constant identified
r1938 voltage constant identified
r1939 reluctance torque constant identified
r1947 optimum load angle identified
r1969 moment of inertia identified
r1973 Encoder pulse number identified
Note:
The encoder pulse number is only determined very imprecisely and is only suitable for making rough checks (p0408). The
sign is negative if inversion is required (p0410.0).
r1984 Pole position identification angular difference
Note:
r1984 indicates the difference of the angular commutation offset before being transferred into p0431.
Figure 7-18
Drive functions
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
Equivalent circuit diagram for induction motor and cable
Data that are accepted (p1960 = 1)
-
-
p0316 motor torque constant
p0317 motor voltage constant
p0328 motor reluctance torque constant
p0327 optimum motor load angle
p0341 Motor moment of inertia
* p0342 ratio between the total moment of inertia and that of
the motor
+ p1498 load moment of inertia
-
p0431 Angular commutation offset
Drive functions
7.1 Servo control
153