Safety Integrated Functions
8.2 General information about SINAMICS Safety Integrated
Prerequisites for the Extended Functions
● Special license for Extended Functions
LED:
– A13000 --> License not sufficient
– LED READY --> Flashes greed/red at 0.5 Hz
● Activation via PROFIsafe or safe on-board terminals
● Safe actual value acquisition (see chapter "Safe actual value acquisition")
● An activated speed controller in the drive
● Overview of hardware components that support the Extended Functions:
8.2.2

Parameter, Checksum, Version, Password

Properties of Safety Integrated parameters
The following applies to Safety Integrated parameters:
● They are kept separate for each monitoring channel.
● During startup, checksum calculations (Cyclic Redundancy Check, CRC) are performed
● Data storage: The parameters will be saved in the non-volatile memory.
288
Unlike the Basic Functions, a special license is required for Safety Integrated Extended
Functions. The associated license key is entered in parameter p9920 in ASCII code. The
license key can be activated via parameter p9921=1. For information on how to generate
the license key for the product "SINAMICS Safety Integrated Extended Functions", read
the section "Licensing". An insufficient license is indicated via the following alarm and
NOTICE
Per single Control Unit, either control via PROFIsafe or the safe on-board terminals is
permitted. Mixed operation is not permitted.
– CU305 Control Unit
– Power Modules blocksize PM340
– Sensor Modules SMC20, SME20/25
– Motors with DRIVE-CLiQ interface (not with resolver encoder)
– Safe Brake Relay (SBM)
on the safety parameter data and checked. The display parameters are not contained in
the CRC.
Function Manual, 10/2008, 6SL3097-4AB10-0BP0