Siemens Sinamics S110 Function Manual page 44

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

Commissioning preparations for PROFIBUS
2.5 Powering-up/powering-down the drive system
Off responses
● OFF1
● OFF2
● OFF3
Control and status messages
Table 2- 3
Power-on/power-off control
Signal name
0 = OFF1
0 = OFF2
0 = OFF3
Enable operation
44
– n_set = 0 is input immediately to brake the drive along the deceleration ramp (p1121).
– When zero speed is detected, the motor holding brake (if parameterized) is closed
(p1215). The pulses are suppressed when the brake application time (p1217) expires.
Zero speed is detected when the actual speed drops below the speed threshold
(p1226) or once the monitoring time (p1227) started when speed setpoint ≤ speed
threshold (p1226) has expired.
– Immediate pulse suppression, the drive coasts to a standstill.
– The motor holding brake (if parameterized) is closed immediately.
– Switching on inhibited is activated.
– n_set = 0 is input immediately to brake the drive along the OFF3 deceleration ramp
(p1135).
– When zero speed is detected, the motor holding brake (if parameterized) is closed.
The pulses are suppressed when the brake application time (p1217) expires. Zero
speed is detected when the actual speed drops below the speed threshold (p1226) or
once the monitoring time (p1227) started when speed setpoint ≤ speed threshold
(p1226) has expired.
– Switching on inhibited is activated.
Internal control word
STWA.00
STWAE.00
STWA.01
STWAE.01
STWA.02
STWA.03
STWAE.03
Binector input
p0840 ON/OFF1
p0844 1. OFF2
p0845 2. OFF2
p0848 1. OFF3
p0849 2. OFF3
p0852 Enable operation
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
PROFdrive/Siemens
telegram 1 ... 111
STW1.0
STW1.1
STW1.2
STW1.3
Drive functions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents