Safety Integrated Functions
8.9 Acceptance test and acceptance report
8.9.3.2

Description of safety functions - Documentation Part 2

Introduction
This example contains the description of a plant; the settings for a specific plant must be
adapted accordingly.
Function table (Example)
Table 8- 16
Mode of operation
Production
Setup
Emergency stop
Comments: --
SI functions for the drive
Table 8- 17
Drive
1
1
1
Comments: --
366
Example table: Active monitoring functions depending on the operating mode, the
protective doors or other sensors
Protective door
closed and locked
unlocked
closed and locked
unlocked
-
Example: functional overview of the safety functions
SI function
SOS (via on-board
terminals)
SLS 1 (via on-board
terminals)
SS1 (via on-board
terminals)
Drive
1
1
1
1
1
Limit
100 mm
50000 mm/min
--
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
Status of monitoring
functions
All deselected
SOS selected
All deselected
SLS 1 selected
SS1 selected
active if
refer to the function table
refer to the function table
Emergency stop triggered
Drive functions