Motor data
Motor data input requires the following parameters:
Table 7- 8
Motor data
Induction motor
p0304 Motor rated voltage
p0305 Motor rated current
p0307 Motor rated power
p0308 Motor rated power factor
p0310 Motor rated frequency
p0311 Motor rated speed
p0320 Motor rated magnetizing current
p0322 maximum motor speed
p0350 motor stator resistance, cold
p0353 motor series inductance
p0354 motor rotor resistance, cold
p0356 motor stator leakage inductance
p0358 motor rotor leakage inductance
p0360 motor magnetizing inductance
p0400ff encoder data
Rating plate data
Input of the rating plate data requires the following parameters:
Table 7- 9
Rating plate data
Induction motor
p0304 rated voltage
p0305 rated current
p0307 rated power
p0308 rated power factor (cos ϕ)
p0310 rated frequency
p0311 rated speed
p0322 maximum motor speed
p0353 motor series inductance
p0400ff encoder data
Since the rating plate data contains the initialization values for identification, you must
ensure that it is entered correctly and consistently to enable the above data to be
determined.
Drive functions
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
Permanent-magnet synchronous motor
p0305 Motor rated current
p0311 Motor rated speed
p0314 Motor pole pair number
p0316 motor torque constant
p0322 maximum motor speed
p0323 maximum motor current
p0341 Motor moment of inertia
p0350 motor stator resistance, cold
p0353 motor series inductance
p0356 motor stator leakage inductance
p0400ff encoder data
Permanent-magnet synchronous motor
p0304 rated voltage
p0305 rated current
p0307 rated power (alternative p0316)
p0311 rated speed
p0314 Motor pole pair number
or p0315 Motor pole pair width
p0322 maximum motor speed
p0323 maximum motor current
p0353 motor series inductance
p0400ff encoder data
Drive functions