Motor data
Motor data input requires the following parameters:
Table 7- 8
Motor data
Induction motor
p0304 Motor rated voltage
•
p0305 Motor rated current
•
p0307 Motor rated power
•
p0308 Motor rated power factor
•
p0310 Motor rated frequency
•
p0311 Motor rated speed
•
p0320 Motor rated magnetizing current
•
p0322 maximum motor speed
•
p0350 motor stator resistance, cold
•
p0353 motor series inductance
•
p0354 motor rotor resistance, cold
•
p0356 motor stator leakage inductance
•
p0358 motor rotor leakage inductance
•
p0360 motor magnetizing inductance
•
p0400ff encoder data
•
Rating plate data
Input of the rating plate data requires the following parameters:
Table 7- 9
Rating plate data
Induction motor
p0304 rated voltage
•
p0305 rated current
•
p0307 rated power
•
p0308 rated power factor (cos ϕ)
•
p0310 rated frequency
•
p0311 rated speed
•
p0322 maximum motor speed
•
p0353 motor series inductance
•
p0400ff encoder data
•
Since the rating plate data contains the initialization values for identification, you must
ensure that it is entered correctly and consistently to enable the above data to be
determined.
Drive functions
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
Permanent-magnet synchronous motor
p0305 Motor rated current
•
p0311 Motor rated speed
•
p0314 Motor pole pair number
•
p0316 motor torque constant
•
p0322 maximum motor speed
•
p0323 maximum motor current
•
p0341 Motor moment of inertia
•
p0350 motor stator resistance, cold
•
p0353 motor series inductance
•
p0356 motor stator leakage inductance
•
p0400ff encoder data
•
Permanent-magnet synchronous motor
p0304 rated voltage
•
p0305 rated current
•
p0307 rated power (alternative p0316)
•
p0311 rated speed
•
p0314 Motor pole pair number
•
or p0315 Motor pole pair width
p0322 maximum motor speed
•
p0323 maximum motor current
•
p0353 motor series inductance
•
p0400ff encoder data
•
Drive functions
7.1 Servo control
149