Integration - Siemens Sinamics S110 Function Manual

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

A motor data set can only be changed using a DDS changeover. The motor data set
changeover is, for example, used for:
● Switching over different motors
● Switching over different windings in a motor (e.g. star-delta changeover)
● Adapting the motor data
SINAMICS S110 can manage up to 2 motor data sets. The number of motor data sets in
p0130 must not exceed the number of drive data sets in p0180.
10.2.5

Integration

Function diagrams (see SINAMICS S110 List Manual)
● 8560 Command Data Sets (CDS)
● 8565 Drive Data Sets (DDS)
● 8575 Motor Data Sets (MDS)
● 8580 Power unit Data Set, PDS
Overview of important parameters (see SINAMICS S110 List Manual)
Adjustable parameters
● p0130 Motor data sets (MDS) number
● p0139 Copy motor data set (MDS)
● p0140 Encoder data sets (EDS) number
● p0180 Drive data sets (DDS) number
● p0186 Motor data set (MDS) number
● p0187 Encoder 1 encoder data set number
● p0188 Encoder 2 encoder data set number
● p0809 Copy command data set (CDS)
● p0810 BI: Command data set selection CDS bit 0
● p0819[0...2] Copy drive data set DDS
● p0820 BI: Drive data set selection DDS, bit 0
Drive functions
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
Basic information about the drive system
10.2 Data sets
469

Hide quick links:

Advertisement

Table of Contents
loading