10.4.6

BICO technology:

Copying drives
When a drive is copied, the interconnection is copied with it.
Binector-connector converters and connector-binector converters
Binector-connector converter
● Several digital signals are converted to a 32-bit integer double word or to a 16-bit integer
● p2080[0...15] BI: PROFIdrive PZD send bit-serial
Connector-binector converter
● A 32-bit integer double word or a 16-bit integer word is converted to individual digital
● p2099[0...1] CI: PROFIdrive PZD selection receive bit-serial
Fixed values for interconnection using BICO technology
The following connector outputs are available for interconnecting any fixed value settings:
● p2900[0...n] CO: Fixed value_%_1
● p2901[0...n] CO: Fixed value_%_2
● p2930[0...n] CO: Fixed value_M_1
Example:
These parameters can be used to interconnect the scaling factor for the main setpoint or to
interconnect an additional torque.
Drive functions
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
word.
signals.
Basic information about the drive system
10.4 BICO technology: Interconnecting signals
479