Siemens Sinamics S110 Function Manual page 261

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

Function diagrams (see SINAMICS S110 List Manual)
● 1550 Setpoint channel
● 2501 Control word sequence control
● 3020 Motorized potentiometer
Overview of important parameters (see SINAMICS S110 List Manual)
● p1030[D] Motorized potentiometer, configuration
● p1035[C] BI: Motorized potentiometer, setpoint, raise
● p1036[C] BI: Motorized potentiometer, setpoint, lower
● p1037[D] Motorized potentiometer, maximum speed
● p1038[D] Motorized potentiometer, minimum speed
● p1039[C] BI: Motorized potentiometer, inversion
● p1040[D] Motorized potentiometer, starting value
● p1041[C] BI: Motorized potentiometer, manual/automatic
● p1042[C] CI: Motorized potentiometer, automatic setpoint
● p1043[C] BI: Motorized potentiometer, accept setpoint
● p1044[C] CI: Motorized potentiometer, setting value
● r1045 CO: Motorized potentiometer, speed setpoint in front of the ramp-function
● p1047[D] Motorized potentiometer, ramp-up time
● p1048[D] Motorized potentiometer, ramp-down time
● r1050 CO: Motorized potentiometer, setpoint after the ramp-function generator
● p1082[D] Maximum speed
Parameterization with STARTER
In the STARTER commissioning tool, the "Motorized potentiometer" parameter screen in the
project navigator under the relevant drive is activated by double-clicking Setpoint channel ->
Motorized potentiometer.
Drive functions
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
generator
Drive functions
7.3 Function modules
261