Drive functions
7.1 Servo control
7.1.6

Current controller

Properties
● PI controller for current control
● Two identical current setpoint filters
● Current and torque limitation
● Current controller adaptation
● Flux control
Closed-loop current control
No settings are required for operating the current controller. Optimization measures can be
taken in certain circumstances.
Current and torque limitation
The current and torque limitations are initialized when the system is commissioned for the
first time and should be adjusted according to the application.
Current controller adaptation
The P gain of the current controller can be reduced (depending on the current) by means of
current controller adaptation. Current controller adaptation can be deactivated with the
setting p1402.2 = 0.
Figure 7-11
Flux controller (for induction motor)
The parameters for the flux controller are initialized when the system is commissioned for the
first time and do not usually need to be adjusted.
Commissioning with STARTER
In the STARTER commissioning tool, the "Current controller" parameter screen is selected
with the
130
Current controller adaptation
icon in the toolbar:
Function Manual, 10/2008, 6SL3097-4AB10-0BP0