Safety Integrated Functions
8.9 Acceptance test and acceptance report
Function test Part 1
General function test, including a check of the wiring/programming
1. Test of shutdown paths
2. Testing stop functions SS1 and SS2
3. Test the forced checking procedure of the inputs and outputs
4. Test of the emergency stop function and of safety circuits
5. Changeover test of SI functions
Function test Part 2
Detailed function test and valuation of SI functions used.
1. Testing the SI function "Safe Operating Stop" (SOS)
2. Test of the SI function "Safely Limited Speed" (SLS)
3. Test of the SI function "Safe Speed Monitor" (SSM)
Conclusion of the report
Report of the commissioning status tested and countersignatures
1. Inspection of SI parameters
2. Check that the existing safety firmware versions are permissible using the table under
3. Logging of checksums (for each drive)
4. Assigning and logging the Safety password
5. RAM to ROM backup and upload of project data to the STARTER and backup of the
6. Countersignature
Appendix
362
(Test of forced dormant error detection at the inputs and outputs)
(with evaluated measurement diagram or measured values)
(with evaluated measurement diagram or measured values)
(with evaluated measurement diagram or measured values)
Siemens "Product Support" on the Internet (see "Safety Integrated firmware versions").
(do not disclose in the report!)