Siemens Sinamics S110 Function Manual page 430

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

Communication PROFIBUS DP
9.1 Communication according to PROFIdrive
A_DIGITAL (digital outputs)
This process data can be used to control the Control Unit outputs.
See function diagram [2497]
Table 9- 27
Description of A_DIGITAL (digital outputs)
Bit
Meaning
0
Digital input/output 8
(DI/DO 8)
1
Digital input/output 9
(DI/DO 9)
2
Digital input/output 10
(DI/DO 10)
3
Digital input/output 11
(DI/DO 11)
4...
Reserved
15
Note:
The bidirectional digital inputs/outputs (DI/DO) can be connected as either an input or an output (see also transmit signal
E_DIGITAL).
MT_STW
Control word for the "central probe" function. Display via r0685.
Table 9- 28
Description of MT_STW (control word for Control Unit)
Bit
Meaning
0
Falling edge probe 1
1
Falling edge probe 2
2
Falling edge probe 3
3
Falling edge probe 4
4
Falling edge probe 5
5
Falling edge probe 6
6...7
Reserved
8
Rising edge probe 1
9
Rising edge probe 2
10
Rising edge probe 3
11
Rising edge probe 4
12
Rising edge probe 5
13
Rising edge probe 6
14..
Reserved
15
430
DI/DO 8 on the Control Unit must be parameterized as an output
(p0728.8 = 1).
DI/DO 9 on the Control Unit must be parameterized as an output
(p0728.9 = 1).
DI/DO 10 on the Control Unit must be parameterized as an output
(p0728.10 = 1).
DI/DO 11 on the Control Unit must be parameterized as an output
(p0728.11 = 1).
Activation of measuring time determination with the next falling
edge
Activation of measuring time determination with the next rising edge
Remarks
Remarks
Function Manual, 10/2008, 6SL3097-4AB10-0BP0
BICO
BI: p0738
BI: p0739
BI: p0740
BI: p0741
BICO
CI: p0682
Drive functions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents