Communication
11.1 Communication according to PROFIdrive
Procedure:
1. Set p0922 ≠ 999.
2. p2038 = set required interface mode.
When positioning telegrams 7, 9, 110, and 111 are set, the "SINAMICS" Interface Mode is
permanently specified (p2038 = 0). This relationship cannot be changed.
When telegrams 102, 103, 105, 106, 116, 118, 125, 126, 136, 138 and 139 are set, the
"SIMODRIVE 611 universal" Interface Mode is permanently specified (p2038 = 1). This
relationship cannot be changed.
When standard telegram 20 is set, the "VIK-NAMUR" Interface Mode is permanently
specified (p2038 = 2). This relationship cannot be changed.
When a telegram that permanently specifies the Interface Mode (e.g. p0922 = 102) is
changed to a different telegram (e.g. p0922 = 3) that does not specify the Interface Mode,
the original setting in p2038 is retained.
11.1.2.2

Information about control words and status words

Overview of control words and setpoints
A detailed overview of the control words and setpoints is contained in the SINAMICS
S120/S150 List Manual in the following function diagrams:
• 2439
• 2440
Overview of status words and actual values
A detailed overview of the status words and actual values is contained in the SINAMICS
S120/S150 List Manual in the following function diagrams:
• 2449
• 2450
646
PROFIdrive - PZD receive signals, profile-specific interconnection
PROFIdrive - PZD receive signals, manufacturer-specific interconnection
PROFIdrive - PZD send signals, profile-specific interconnection
PROFIdrive - PZD send signals, manufacturer-specific interconnection
Function Manual, (FH1), 04/2014, 6SL3097-4AB00-0BP4