No command deletes the RMON alarm entry.
rmon alarm alarm number variable sample interval {absolute | delta} rising-threshold value [rising-
event-index] falling-threshold value [falling-event-index] [startup {rising | falling | rising-falling}]
[owner string]
no rmon alarm alarm number
Parameters
Alarm Index
Alarm Variable
Alarm Interval
Alarm Absolute Value
Alarm Rising Threshold
Alarm Rising Event Index
Alarm Falling Threshold
Alarm Falling Event Index
Alarm Startup Alarm
Alarm Owner
Default
The default is None.
Command Mode
Global Config
Example
The following is an output example.
(Routing)(Config)#rmon alarm 1 ifInErrors.2 30 absolute rising-threshold 100 1
falling-threshold 10 2 startup rising owner myOwner
The following is an output example.
(Routing)(Config)#no rmon alarm 1
Unique index identifying an entry in the alarm table. Each entry defines
a diagnostic sample at a particular interval for an object on the device.
The range is 1 to 65535.
Variable object identifier to be sampled. Only variables that resolve to an
ASN.1 primitive type of integer.
Data sampling and comparison (seconds) of the rising and falling
threshold. The range is 1 to 2147483647. The default is 1.
Statistical value during the sampling period. This object is a read-only,
32-bit signed value.
Rising threshold for the statistical sample. The range is 2147483648 to
2147483647. The default is 1.
Rising event index once threshold is crossed. The range is 1 to 65535.
The default is 1.
Falling threshold for the statistical sample. The range is 2147483648 to
2147483647. The default is 1.
Falling event index once threshold is crossed. The range is 1 to 65535.
The default is 2.
Designate alarm type. Possible values are rising, falling or both rising-
falling. The default is rising-falling.
The owner string associated with the alarm entry. The default is monitor
Alarm.