5000 Series Layer 2/3 Managed Data Center Switch CLI Reference Guide
6-46
vxlan tenant-system
This command is used to configure the forwarding entity for the tenant system MAC address mac-addr in
the specified VN that can be reached through the access interface. The tenant systems can be configured
one by one. Typically, the system learns the MAC address for tenant systems automatically from the
traffic received on the access interface. The tenant systems MAC address mac-addr can be configured
when accessing the interface to prevent initial flooding. If a tenant system has been configured on an
interface, then the configuration overrides the learning for the indicated MAC address in that VN.
Note: This command is only valid for physical and port-channel interfaces, and the configured interface
ought to also be a member of VLAN associated with the specified VNID.
The MAC addresses for the tenant system are maintained in a separate table and are not listed in the
FDB mac-address table. These addresses internally consume shared resources for system hardware
layer 2 address tables. As such, the maximum number of tenant systems configured or learned is
dependent upon the number of resources that remain in the hardware layer 2 table, with that number
being dynamic in nature.
The allowed configurable range for the VNID is 1 to 16777214, while the use of 16777215 is reserved for
internal purposes.
A maximum of 24 tenant systems per physical or port-channel interface can be configured.
The no command is used to delete the configured tenant system forwarding entry on an interface when
both the VNID and the tenant system mac-address are specified. The command cannot be utilized in
order to delete a dynamically-learned tenant system association on the interface in a specified VNID VN.
Note: When the removal of an access port configuration of the VN specified by VNID occurs, then all of
the forwarding entries configured by the user and learned by the switch on that access port, if any, are
also removed due to the removal of the port participation of the associated VLAN.
vxlan vnid tenant-system mac-addr
no vxlan vnid tenant-system mac-addr
Parameters
vnid
mac-addr
Default
The default is Tenant MAC addresses not associated with the VN.
Command Mode
Interface Config
6-47
vxlan udp-dst-port
This command is used to configure a specific UDP port to be the VXLAN UDP destination port of the
switch. All the VXLANs on the switch, when encapsulating, will then utilize this UDP port as the UDP
Indicates the VXLAN VNID.
Indicates the MAC Address of the tenant system.